Victron 48V 5000VA MultiPlus-II 48/5000/70-50 GX Inverter/Charger
Victron 48V 5000VA MultiPlus-II 48/5000/70-50 GX Inverter/Charger
9000 W Peak Power, 70 A Charging, Built-In GX Monitoring
Highlights:Integrated LCD: LCD screen displaying real-time battery voltage, state of charge, and power usage,Built-in GX Device: Integrated GX device for advanced system monitoring and remote control,Steel Enclosure: Durable blue RAL 5012 powder-coated steel enclosure with IP21 protection rating,Connection Interface: Bottom terminal area for AC input, output, and battery cable connections.
Key features: Integrated PowerControl and PowerAssist functionality, Supports simultaneous grid and generator inputs, Lithium battery compatible multi-stage charging, Dedicated 'no break' AC output for critical electronics.
This grid-parallel system layout uses an external current sensor or power meter to optimise self-consumption and intelligently manage solar energy feed-in.
The Victron Remote Management (VRM) app provides full control and monitoring of your power system from any iOS or Android device.

DESCRIPTION
Victron MultiPlus-II GX Inverter/Charger: Integrated Power and Monitoring for off-grid and mobile energy systems
Advanced Inverter/Charger with Built-In GX Control
The Victron MultiPlus-II GX combines a powerful inverter/charger with an integrated GX monitoring device, delivering a complete energy management solution for off-grid and mobile energy systems. This all-in-one unit provides pure sine wave AC power from your battery bank, intelligent battery charging from shore or generator, and seamless system monitoring via the built-in LCD and Wi-Fi connectivity. With PowerControl and PowerAssist technology, it prevents nuisance tripping of shore breakers and supplements limited grid or generator power with battery energy during peak loads.
Designed for demanding Australian conditions, the MultiPlus-II GX operates reliably from -40 to +65 °C with fan-assisted cooling. Its robust steel enclosure (RAL 5012 blue) and IP22 protection make it suitable for protected installations in vehicles, vessels, and off-grid buildings. The integrated GX device provides VE.Can, USB, Ethernet, VE.Direct, and Wi-Fi interfaces, enabling remote monitoring and control via the Victron Remote Management (VRM) portal and the VictronConnect app.
Key Features
- Integrated GX device with 2 x 16 character LCD for real-time system status
- PowerControl and PowerAssist prevent shore breaker trips and boost weak grid/generator supplies
- Pure sine wave output with 9000 W peak power for demanding loads
- Multi-stage adaptive charging with 70 A charge current for rapid battery replenishment
- VE.Bus communication for parallel and three-phase operation (only one GX unit needed)
- Dual AC outputs: one 'no-break' output for critical loads, one programmable auxiliary output
- Comprehensive connectivity: VE.Can, USB, Ethernet, VE.Direct, Wi-Fi
- Wide DC input voltage range: 38 - 66 V
- Programmable relay and two general-purpose communication ports for custom integrations
- Battery temperature sensor included for temperature-compensated charging
Intelligent Power Management
The MultiPlus-II GX excels in managing limited AC sources. PowerControl automatically adjusts battery charging current to prevent overload of the shore or generator supply, while PowerAssist instantly supplements the AC source with battery power when demand exceeds the available current. This is invaluable for off-grid and mobile energy systems where shore power is often limited, allowing you to run high-power appliances without tripping breakers or needing a larger generator.
Seamless System Integration
With the built-in GX device, you can monitor and control your entire energy system from anywhere. The LCD displays battery state of charge, inverter load, solar input, and more. Connect via Wi-Fi to the VictronConnect app for configuration and live data, or use the VRM portal for advanced logging and remote firmware updates. The VE.Can port interfaces with compatible CAN-bus batteries and Victron VE.Can MPPTs, while VE.Direct connects to additional Victron devices. Ethernet provides a stable wired network connection for permanent installations.
Reliable Power for Critical Loads
The MultiPlus-II GX features a dedicated 'no-break' AC output that maintains power to essential equipment during grid failures or when switching between shore and inverter power. The transfer switch operates in less than 20 milliseconds, ensuring computers, medical devices, and other sensitive electronics continue without interruption. This makes it ideal for off-grid and mobile energy systems where uptime is critical.
Built for Australian Conditions
Engineered to withstand harsh environments, the MultiPlus-II GX operates in temperatures from -40 to +65 °C and up to 95% non-condensing humidity. The fan-assisted cooling ensures reliable performance even under sustained high loads. The steel enclosure with RAL 5012 blue powder coating provides durability and corrosion resistance for mobile and marine applications.
Ready to upgrade your energy system with integrated monitoring and intelligent power management? Order the Victron MultiPlus-II GX today and experience reliable, connected power for your off-grid and mobile energy systems.
SPECIFICATIONS
Specifications
| PowerControl & PowerAssist | Yes |
|---|---|
| Transfer Switch | 50 A |
| Maximum AC Input Current | 50 A |
| Auxiliary Output | Yes (32 A) |
| DC Input Voltage Range | 38 - 66 V |
| Output | Output voltage: 230 VAC ± 2 %; Frequency: 50 Hz ± 0.1 % |
| Cont. Output Power at 25 °C (VA) | 5000 VA |
| Cont. Output Power at 25 °C (W) | 4000 W |
| Cont. Output Power at 40 °C | 3700 W |
| Cont. Output Power at 65 °C | 3000 W |
| Maximum Apparent Feed-In Power | 5000 VA |
| Peak Power | 9000 W |
| Maximum Efficiency | 96 % |
| Zero Load Power | 18 W |
| Zero Load Power in AES Mode | 12 W |
| Zero Load Power in Search Mode | 2 W |
| AC Input | Input voltage range: 187-265 VAC; Input frequency: 45 - 65 Hz |
| Charge Voltage 'Absorption' | 57.6 V |
| Charge Voltage 'Float' | 55.2 V |
| Storage Mode | 52.8 V |
| Maximum Battery Charge Current | 70 A |
| Battery Temperature Sensor | Yes |
| Interfaces | BMS-Can, USB, Ethernet, VE.Direct, Wi-Fi |
| External AC Current Sensor (Optional) | 100 A |
| Programmable Relay | Yes |
| VE.Bus Communication Port | For parallel and three phase operation, remote monitoring and system integration |
| General Purpose Com. Port | Yes, 2 x |
| Remote On-Off | Yes |
| Operating Temperature Range | -40 to +65 °C (fan assisted cooling) |
| Humidity (Non-Condensing) | Max 95 % |
| Material & Colour | Steel, blue RAL 5012 |
| Protection Category | IP22 |
| Battery-Connection | M8 bolts |
| 230 V AC-Connection | Screw terminals 13 mm² (6 AWG) |
| Weight | 31 kg |
| Dimensions (H x W x D) | 565 x 323 x 148 mm |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission, Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
| Uninterruptible Power Supply | IEC 62040-1 |
| SKU: | VIC-PMP482506000 |
| Barcode: | 8719076048824 |
| Model #: | PMP482506000 |
| MPN: | PMP482506000 |
WARRANTY
Victron Energy Limited Warranty Policy
Direct Customers
Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.
End-Users
Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website https://www.victronenergy.com/support. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website https://www.victronenergy.com/support will provide further guidance on the procedure for end-users to make a claim under this limited warranty.
If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.
Warranty
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.
For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.
During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.
This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
- Reversed battery polarity.
- Inadequate connection.
- Mechanical shock or deformation.
- Contact with liquid or oxidation by condensation.
- Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
- Breakage or damage due to lightning.
- Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
- For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.
This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.
Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.
In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.
If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.
All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.
The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.
Life Support Policy
As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.
Warranty on repairs for products outside their warranty period
The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.
Applicable law
This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.
Contact details
Victron Energy B.V. | De Paal 35, 1351 JG Almere, The Netherlands | https://www.victronenergy.com/support