Australian Owned & Operated Family BusinessAustralian Family Business
Before & After Sales SupportBefore & After Sales Support
10+ Years Solar Industry ExperienceA Decade of Industry Experience
High Quality Green ProductsHigh Quality & Sustainable Products
Fast ShippingFast Dispatch
Great Prices and Price Match GuaranteeVictron & Enerdrive Price Match Guarantee
Large Range of DIY KitsRange of DIY Kits

Victron 48V 6000VA Multi RS Solar 48/6000/100-450/80 Inverter/Charger/MPPT 450V/100A

Plus 80A Mains Charger


Regular price $2,848.39
$2,889.70
/
Availability: Expected this week
View all products from Victron

We’re here to help you get it right! Give us a quick call to verify your installation and ensure a seamless setup.

Guaranteed Safe and Secure Checkout
American Express Apple Pay Google Pay MastercardPayPalShop Pay Union PayVisa

0
Front view of blue Victron Multi RS Solar inverter charger with LCD status display

Victron 48V 6000VA Multi RS Solar 48/6000/100-450/80 Inverter/Charger/MPPT 450V/100A

DESCRIPTION

Victron Multi RS Solar 48/6000 Dual Tracker: A New Standard in Solar Energy Management

Elevate your energy system with the Victron Multi RS Solar 48/6000 Dual Tracker, the premier 48V 6000VA inverter/charger with a dual MPPT capable of 450V/100A. This innovative solution is designed for optimal flexibility and efficiency, ensuring your energy needs are met with precision across a variety of operating modes.

Versatile Operating Modes for Every Need

  • Hybrid Mode: Harness solar power to its fullest by storing excess energy in a battery for use at night or during peak demand, with the ability to supplement power from the battery when consumption exceeds grid capacity.
  • Backup Mode: Experience uninterrupted power with an automatic switch to backup during grid outages, keeping your critical systems running smoothly.
  • Off-Grid Mode: Gain complete independence with the ability to operate without any grid connection, perfect for remote locations.
  • Generator Mode: Optimize generator use by controlling run-hours and supplementing with battery power when demand outstrips generator capacity.

Advanced PowerControl and PowerAssist Features

Set maximum currents for your grid or generator to prevent overloads with the PowerControl function. The Multi RS Solar takes it a step further with PowerAssist, supplementing insufficient power with battery reserves during peak demand and recharging the battery when the load decreases.

Dual MPPT for Maximum Solar Harvesting

With dual MPPT, the Multi RS Solar 48/6000 ensures that you're capturing the maximum energy from your solar panels, even in varying lighting conditions. This feature allows for two independent solar arrays, optimizing energy harvest and providing redundancy.

Intuitive Monitoring with Display, Bluetooth, and VictronConnect App

Keep a close eye on your system's health with the integrated display showing battery, inverter, and solar parameters. For remote monitoring and control, the VictronConnect app pairs seamlessly with your device via Bluetooth.

Scalable PV Capacity

Your solar capacity grows with you. Start with the integrated 6 kWp PV capacity and expand by adding solar chargers for AC or DC coupling. Integrate additional PV Inverters with automatic power control for a tailored energy solution.

Robust Communication and Connection Options

Monitor, log data, and update firmware remotely via VE.Can connection to a GX device. For remote monitoring, connect with VE.Direct to a GlobalLink 520. Programmable relays, temperature sensors, and voltage sensors ensure a customizable and secure setup.

The Victron Multi RS Solar 48/6000 Dual Tracker is not just an inverter/charger—it's the heart of your solar energy system. It's designed to adapt to your changing power needs while providing efficiency and reliability. Step into the future of energy management and make the smart move to a system that grows with your energy demands.

SPECIFICATIONS

Specifications

Model Multi RS Solar 48/6000 Dual Tracker
PowerControl & PowerAssist Yes
Transfer switch 50 A
Maximum AC input and pass-through current 50 A
INVERTER  
DC Input voltage range (1) 38 – 62 V
AC Output (2) Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0,1 % Maximum continuous inverter current: 25 Aac
Continuous output power at 25 °C Increases linearly from 4800 W at 46 VDC to 5300 W at 52 VDC
Continuous output power at 40 °C 4500 W
Continuous output power at 65 °C 3000 W
Peak power (3) 9 kW for 3 seconds 7 kW for 4 minutes
Short-circuit output current 45 A
Max. AC output overcurrent protection 30 A
Efficiency 96.5 % at 1 kW load 94 % at 5 kW load
Zero load power consumption 20 W
Low Battery shutdown 37.2 V (adjustable)
Low battery restart 43.6 V (adjustable)
SOLAR  
Maximum open circuit PV array voltage^{(4)} 450 V
Start-up voltage 120 V
MPPT operating voltage range 80 – 450 V
Maximum operational PV input current limit 13 A
Maximum PV conversion power 6 kW total – 3 kW per tracker
Maximum PV short circuit current 16 A
Earth leakage trip level 30 mA
Isolation fail level (detection before start-up) 100 kΩ
CHARGER  
AC Input Nominal Voltage: 230 VAC, Input voltage range: 187-265 VAC Nominal frequency: 50 Hz, Input frequency: 45-65 Hz AC inrush current: NA
Programmable charge voltage range (5) 36 – 60 V
Charge voltage 'absorption' Default setting: 57.6 V (adjustable)
Charge voltage 'float' Default setting: 55.2 V (adjustable)
Maximum charge current from AC (6) 88 A @ 57.6 VDC
Total maximum charge current (AC + PV) 100 A DC
Battery temperature sensor Included
Battery voltage sense Yes
GENERAL  
Auxiliary output (AC-out-2) (7) Yes
3-phase and parallel operation 3-phase support with one unit per phase. Parallel not supported.
Programmable relay (8) Yes
Protections (9) a - g
Data communications ports (10) VE.Direct, VE.Can & Bluetooth
Bluetooth frequency & power 2402 - 2480 Mhz, 4 dBm
Programmable analog/digital input/output ports Yes, 2x
Remote on-off Yes
Operating temperature range -40 to +65 °C (fan assisted cooling)
Maximum altitude 2000 m
Humidity (non-condensing) max 95 %
ENCLOSURE  
Material & Colour steel, blue RAL 5012
Protection category IP21 Protective Class: I
Battery-connection M8 bolts
PV Connection 2 strings, each with positive and negative MC4
230 VAC-connection Screw terminals 10 mm² (6 AWG)
Weight 12.3 kg
Dimensions (hxwxd) 425 x 460 x 125 mm
STANDARDS  
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, Pollution Degree 2
Overvoltage Category Battery: OVC 1, PV port: OVC II, AC in / AC out: OVC III
1) Minimum start-up voltage is 41 VDC. Over-voltage disconnect: 65,5 V. 2) Can be adjusted to 240 VAC and 60 Hz 3) Peak power capacity and duration depends on start temperature of heatsink. Mentioned times are with cold unit. 4) The maximum PV voltage should not exceed 8x battery float voltage. If for example the float voltage of the battery is 50 V, the maximum PV voltage should not exceed 8 x 50 = 400 V. 5) The Charger set points (float & absorption) can be set to max 60 V. The output voltage at the charger terminals can be higher due to compensation for temperature & voltage drop over the battery cables. The maximum output current is reduced on a linear basis from full current at 60 V to 5 A at 62 V. The equalization voltage can be set to max 62 V, the equalization current percentage can be set to max 6 %. 6) The maximum charge current from AC sources depends on input voltage and battery current. At 230V input and 57.6V battery voltage, and 25C ambient, the maximum charge current is 88 A. See manual, limitations section, for further details. 7) AC-out-2 is connected directly to the AC input and intended for non-critical loads. The AC-out-2 load is taken into account by PowerControl & PowerAssist. 8) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC 9) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) solar earth leakage. 10) Not currently compatible with VE.Smart Networks. Connection to a GX device (i.e. Cerbo GX) must be made via the VE.Can interface. The VE.Direct interface is for connection to the GlobalLink 520.

SKU: VIC-PMR482602020
Barcode: 8719076056690
Model #: PMR482602020
MPN: PMR482602020

WARRANTY

Victron Energy Limited Warranty Policy

Direct Customers

Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.

End-Users

Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website https://www.victronenergy.com/support. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website https://www.victronenergy.com/support will provide further guidance on the procedure for end-users to make a claim under this limited warranty.

If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.

Warranty

Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.

For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.

During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.

This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:

  • Reversed battery polarity.
  • Inadequate connection.
  • Mechanical shock or deformation.
  • Contact with liquid or oxidation by condensation.
  • Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
  • Breakage or damage due to lightning.
  • Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
  • For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.

This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.

This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.

Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.

As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.

In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.

If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.

All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.

The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.

Life Support Policy

As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.

Warranty on repairs for products outside their warranty period

The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.

Transport

It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.

Severability

If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.

Applicable law

This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.

Contact details

Victron Energy B.V. | De Paal 35, 1351 JG Almere, The Netherlands | https://www.victronenergy.com/support

RECENTLY VIEWED PRODUCTS