Victron Skylla-i 24/100 (3): Industrial-Grade 24V 100A Multi-Bank Battery Charger
Advanced Adaptive Charging for Professional Marine, Automotive, and Off-Grid Systems
The Victron Skylla-i 24/100 (3) is a high-performance, microprocessor-controlled battery charger engineered for demanding environments where reliability and precision are critical. Delivering up to 100 A across three fully rated outputs, it simultaneously charges three independent battery banks without compromise, making it an ideal solution for commercial vessels, emergency vehicles, and large off-grid power systems.
Unlike conventional chargers that divide current between outputs, each of the three isolated outputs can supply the full 100 A, ensuring rapid, complete charging even under heavy load. The integrated 7-stage adaptive charge algorithm automatically adjusts absorption time based on depth of discharge, preventing overcharging after shallow cycles and ensuring full recovery after deep discharges. This extends battery service life and reduces maintenance in critical applications.
Built for Harsh Environments
Housed in a robust aluminium epoxy powder-coated case with a drip shield and stainless steel fixings, the Skylla-i withstands heat, humidity, and salt air. Internal circuit boards receive an acrylic conformal coating for maximum corrosion resistance, while temperature sensors automatically derate output current under extreme conditions to protect power components. These features make it a trusted choice for marine, coastal, and industrial installations where lesser chargers fail prematurely.
Intelligent Battery Management
The Skylla-i incorporates Victron's advanced BatterySafe mode, which limits voltage rise once gassing voltage is reached, preventing excessive gassing and electrolyte loss. The Storage mode reduces float voltage to 26.4 V after 24 hours of inactivity, minimising positive plate corrosion and electrolyte stratification, with a weekly refresh cycle to prevent sulphation. An included battery temperature sensor enables automatic voltage compensation, essential for sealed lead-acid batteries and environments with wide temperature swings.
Flexible Integration and Control
With a galvanically isolated CAN bus (NMEA2000) interface, the charger supports synchronised parallel operation of multiple units via RJ45 cables, scaling to meet large battery banks. A rotary switch, DIP switches, and potentiometers allow fine-tuning of charge parameters for specific battery chemistries, including LiFePO4. Remote on-off control via a BMS relay or optocoupler output enables seamless integration into lithium systems, while the voltage sense facility compensates for cable losses, ensuring precise charge voltage at the battery terminals.
Key Features
- Three fully rated 100 A outputs for simultaneous multi-bank charging
- 7-stage adaptive charge algorithm with variable absorption time
- BatterySafe mode prevents excessive gassing during high-current charging
- Storage mode reduces float voltage to extend battery life during inactivity
- Temperature compensation with included sensor for optimal charging in all climates
- CAN bus (NMEA2000) interface for parallel operation and system integration
- Voltage sense inputs compensate for cable voltage drop
- Accepts both AC (185-265 V) and DC (180-350 V) input for versatile power sources
- Conformal coated electronics and stainless steel hardware for corrosion resistance
- Can function as a stabilised power supply for DC loads without batteries
Applications
This charger is purpose-built for professional and heavy-duty applications where downtime is not an option. Typical use cases include:
- Commercial marine vessels with multiple battery banks (house, start, thruster)
- Emergency service vehicles requiring reliable, fast charging
- Off-grid solar systems with large lead-acid or lithium battery banks (500-1000 Ah)
- Industrial backup power and telecommunications sites
- Mobile workshops and field service trucks
Why Choose the Skylla-i Over Standard Chargers?
Standard multi-bank chargers often split total current across outputs, leading to extended charge times when one bank is deeply discharged. The Skylla-i's three full-current outputs eliminate this bottleneck. Its adaptive algorithm and environmental hardening reduce the risk of battery damage from overcharging, undercharging, or corrosion-related failures, common in generic-grade chargers. For lithium systems, the CAN bus interface provides precise control beyond simple on-off switching, ensuring safe, efficient charging profiles.
With a power factor of 0.98 and wide input voltage range, it operates efficiently on generators and unstable grid supplies, reducing generator run time and fuel consumption. The alarm relay (DPST) provides remote monitoring of charge status or fault conditions, enhancing system oversight.
Technical Highlights
The charger connects via M8 bolt terminals for secure, low-resistance battery connections, and the 230 VAC input uses screw-clamp terminals accepting up to 10 mm² cable. Forced cooling with temperature-controlled fans maintains full output up to 40°C ambient, with derating to 60°C. The IP21 rating suits protected indoor or enclosed installations.
Note: For optimal performance, ensure adequate ventilation and use appropriately sized cables to minimise voltage drop.
Power Your Critical Systems with Confidence
Equip your vessel, vehicle, or off-grid installation with the Victron Skylla-i 24/100 (3) and experience professional-grade charging that protects your battery investment. Order today to ensure uninterrupted power when it matters most.
SPECIFICATIONS
Specifications
| Input Voltage (VAC) | 230 V |
|---|---|
| Input Voltage Range (VAC) | 185-265 V |
| Input Voltage Range (VDC) | 180-350 V |
| Maximum AC Input Current @ 180 VAC | 20 A |
| Frequency (Hz) | 45-65 Hz |
| Power Factor | 0.98 |
| Output Voltage Range (VDC) | 20-36 V |
| Charge Voltage 'Absorption' (VDC) | 28.8 V |
| Charge Voltage 'Float' (VDC) | 27.6 V |
| Charge Voltage 'Storage' (VDC) | 26.4 V |
| Charge Current (A) | 3 x 100 A (Max total output: 100 A) |
| Charge Algorithm | 7 Stage Adaptive |
| Battery Capacity (Ah) | 500-1000 Ah |
| Charge Algorithm, Li-Ion | 3 Stage, with on-off control or CAN bus control |
| Temperature Sensor | Yes |
| Can Be Used As Power Supply | Yes |
| Remote On-Off Port | Yes (Can be connected to a Li-Ion BMS) |
| VE.Can Communication Port | Two RJ45 connectors, NMEA2000 protocol, galvanically isolated. Integrated 12 V CAN-bus power supply, 30 V DC maximum. |
| Synchronised Parallel Operation | Yes, with VE.Can |
| Alarm Relay | DPST. AC rating: 240 VAC / 4 A. DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC. |
| Forced Cooling | Yes |
| Protection | Battery reverse polarity (fuse), output short circuit, over temperature |
| Operating Temp. Range | -20 to 60 °C (Full output current up to 40 °C) |
| Humidity (Non-Condensing) | Max 95% |
| Material & Colour | Aluminium (Blue RAL 5012) |
| Battery Connection | M8 bolts |
| 230 VAC Connection | Screw-clamp 10 mm² (AWG 7) |
| Protection Category | IP 21 |
| Weight | 7 kg (16 lbs) |
| Dimensions (H x W x D) | 405 x 250 x 150 mm (16.0 x 9.9 x 5.9 in) |
| Safety | EN 60335-1, EN 60335-2-29 |
| Emission | EN 55014-1, EN 61000-6-3, EN 61000-3-2 |
| Immunity | EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3 |
| SKU: | VIC-SKI024100002 |
| Barcode: | 8719076026259 |
| Model #: | SKI024100002 |
| MPN: | SKI024100002 |
WARRANTY
Victron Energy Limited Warranty Policy
Direct Customers
Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.
End-Users
Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website https://www.victronenergy.com/support. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website https://www.victronenergy.com/support will provide further guidance on the procedure for end-users to make a claim under this limited warranty.
If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.
Warranty
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.
For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.
During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.
This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
- Reversed battery polarity.
- Inadequate connection.
- Mechanical shock or deformation.
- Contact with liquid or oxidation by condensation.
- Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
- Breakage or damage due to lightning.
- Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
- For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.
This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.
Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.
In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.
If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.
All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.
The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.
Life Support Policy
As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.
Warranty on repairs for products outside their warranty period
The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.
Applicable law
This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.
Contact details
Victron Energy B.V. | De Paal 35, 1351 JG Almere, The Netherlands | https://www.victronenergy.com/support