Australian Owned & Operated Family BusinessAustralian Family Business
Before & After Sales SupportBefore & After Sales Support
10+ Years Solar Industry ExperienceA Decade of Industry Experience
High Quality Green ProductsHigh Quality & Sustainable Products
Fast ShippingFast Dispatch
Great Prices and Price Match GuaranteeVictron & Enerdrive Price Match Guarantee
Large Range of DIY KitsRange of DIY Kits

Victron Lynx Smart BMS 1000 NG (NextGen) M10

1000A Continuous Rating with Built-In Pre-Charge and Redundancy


Regular price $2,356.20
$1,717.10
/
Availability: In Stock at Victron Warehouse Allow up to 5 days before dispatch
View all products from Victron
Guaranteed Safe and Secure Checkout
Apple Pay Google Pay MastercardPayPalShop Pay Visa

0
Front view of the blue Victron Lynx Smart BMS 1000 NextGen with IP22 rating

Victron Lynx Smart BMS 1000 NG (NextGen) M10

DESCRIPTION

Next-Generation Battery Management for High-Capacity Lithium Systems

The Victron Lynx Smart BMS 1000 NG (NextGen) stands as the ultimate command centre for your energy storage, specifically engineered to integrate seamlessly with Victron Lithium Battery Smart models. Designed for complex power setups in marine vessels, off-grid properties, and high-demand industrial applications, this advanced Battery Management System ensures your 12V, 24V, or 48V lithium iron phosphate (LiFePO4) battery banks operate safely and efficiently.

Unlike standard controllers, the Lynx Smart BMS goes beyond simple cell balancing. It actively protects your power system from deep discharges, overcharging, and extreme temperatures, prolonging the lifespan of your heavy-duty battery arrays. With a robust 1000A continuous current rating and surge capabilities up to 1200A for five minutes, it easily handles the high loads of demanding inverter networks and parallel configurations.

Integrated Pre-Charge Circuit and Primary Safety Contactor

One of the most critical challenges when powering up high-capacity inverter systems is managing the initial rush of electrical current. The integrated pre-charge circuit resolves this completely. By safely charging the internal capacitors of connected inverters before the main contactor engages, it prevents damaging inrush currents that can degrade components over time. This eliminates the need for manual pre-charging steps or external resistors, reducing installation complexity and lowering the risk of hardware faults.

Additionally, the built-in safety contactor acts as a dependable secondary safety mechanism. It provides an immediate physical disconnect in the event of a critical system fault, isolating your batteries to prevent severe damage. This contactor can also be controlled remotely, giving users the ability to manually shut down the system during maintenance or long-term storage.

Parallel Redundancy for Mission-Critical Power

The "NG" NextGen series introduces a highly requested feature for complex electrical architectures: parallel redundancy. By installing multiple Lynx Smart BMS units in parallel, system builders can drastically increase overall storage capacity while establishing a failsafe network. In the event of an isolated communication or hardware issue, the redundant architecture allows your system to maintain safe, continuous operation. This ensures your off-grid home or commercial marine vessel never experiences an unexpected total power loss.

Comprehensive Monitoring and System Integration

Full visibility into your power usage is crucial for long-term reliability. Equipped with built-in Bluetooth, this Victron BMS allows installers and end-users to monitor real-time battery voltage, temperature data, and system health directly from a smartphone or tablet using the VictronConnect app.

For more advanced setups, the included VE.Can port allows direct communication with Victron GX devices, such as the Cerbo GX. This enables global remote monitoring via the VRM portal. Furthermore, native NMEA 2000 compatibility ensures the system integrates flawlessly into modern marine networks, displaying crucial energy metrics right on your glass bridge or multi-function display.

Key Features

  • High Current Capacity: 1000A continuous current rating via heavy-duty M10 tinned copper busbars.
  • Built-in Pre-Charge: Protects inverter capacitors by safely managing inrush currents during startup.
  • Integrated Safety Contactor: Reliable hardware disconnect for critical faults and remote system isolation.
  • Parallel Redundancy: Connect multiple NextGen BMS units for scalable capacity and fault-tolerant continuous operation.
  • Advanced Diagnostics: Built-in Bluetooth and VE.Can connectivity for local and remote VictronConnect monitoring.
  • Multi-Voltage Support: Fully compatible with 12V, 24V, and 48V Victron Lithium Smart battery configurations.

Secure the core of your energy infrastructure with robust protection and intelligent control. Upgrade your off-grid or marine electrical architecture with the Victron Lynx Smart BMS 1000 NG and maintain complete visibility over your power reserves today.

SPECIFICATIONS

Specifications

Lynx Smart BMS 1000 A
Power  
Battery voltage range 9 – 60 VDC
Maximum input voltage 75 VDC
Supported system voltages 12, 24 or 48 V
Reverse polarity protection No
Main safety contactor continuous current rating 1000 A continuous
Main safety contactor peak current rating 1200 A for 5 minutes
Power consumption OFF mode 0.3 mA for all system voltages
Power consumption in Standby mode Approximately 0.6 W (50 mA at 12 V)
Power consumption in ON mode Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays
Minimum load resistance for pre-charging 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems
AUX output maximum current rating 1.1 A continuous, protected by resettable fuse
Allow-to-charge port Maximum current rating 0.5 A at 60 VDC, protected by resettable fuse
Allow-to-discharge port Maximum current rating 0.5 A at 60VDC, protected by resettable fuse
Alarm relay (SPDT) Maximum current rating 2 A at 60 VDC
Connections  
Busbar M10 (Torque: 33 Nm) (17 Nm for units with a serial number before HQ2340XXXX)
VE.Can RJ45
I/O Removable multi-connector with screw terminals
Battery BTV cables Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system
Lynx Distributor fuse monitoring (up to 4 modules) RJ10 (cable ships with each Lynx Distributor)
Physical  
Enclosure material ABS
Enclosure dimensions (h x w x d) 230 x 180 x 100 mm
Unit weight 2.7 kg
Busbar material Tinned copper
Busbar dimensions (h x w) 8 x 30 mm
Environmental  
Operating temperature range -40 °C to +60 °C
Storage temperature range -40 °C to +60 °C
Humidity Max. 95 % (non-condensing)
Protection class IP22
Standards  
Safety EN-IEC 63000:2018
EMC EN-IEC 61000-6-3:2007/A1:2011/AC:2012
QMS NEN-EN-ISO 9001:2015

SKU: VIC-LYN034170310
Barcode: 8719076063568
Model #: LYN034170310
MPN: LYN034170310

WARRANTY

Victron Energy Limited Warranty Policy

Direct Customers

Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.

End-Users

Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website https://www.victronenergy.com/support. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website https://www.victronenergy.com/support will provide further guidance on the procedure for end-users to make a claim under this limited warranty.

If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.

Warranty

Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.

For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.

During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.

This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:

  • Reversed battery polarity.
  • Inadequate connection.
  • Mechanical shock or deformation.
  • Contact with liquid or oxidation by condensation.
  • Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
  • Breakage or damage due to lightning.
  • Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
  • For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.

This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.

This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.

Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.

As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.

In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.

If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.

All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.

The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.

Life Support Policy

As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.

Warranty on repairs for products outside their warranty period

The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.

Transport

It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.

Severability

If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.

Applicable law

This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.

Contact details

Victron Energy B.V. | De Paal 35, 1351 JG Almere, The Netherlands | https://www.victronenergy.com/support

RECENTLY VIEWED PRODUCTS

Add notes to your order

Powering Your Adventure

We gave it full sun... ☀️

Try  225W Solar Panel  Victron Inverter  

Popular Products


Official Pricing Reference

Shipping Calculator