5x Victron 400A 80V ANL Fuse
5x Victron 400A 80V ANL Fuse
High-capacity 400A ANL fuses designed for reliable 80V DC circuit protection.
Key features: High-current 400A rating for primary circuit protection, 80V DC maximum voltage rating suitable for 12V, 24V, and 48V systems, Heat-resistant ceramic body construction for safety, Slotted terminal design compatible with standard ANL fuse holders.
Highlights:Slotted Terminal: Tin-plated copper terminals with open slots for easy installation onto studs,Ceramic Housing: Durable heat-resistant ceramic body provides superior thermal protection,Inspection Window: Clear central window allows for quick visual verification of fuse status. 
DESCRIPTION
Victron 400A 80V ANL Fuse (5 Pack)
Safeguard your high-current off-grid, marine, and mobile power systems with the Victron 80V 400A ANL Fuse. Engineered for heavy-duty DC applications, this package of five precision-manufactured ANL fuses provides critical overcurrent protection for demanding electrical circuits. The 80V DC rating makes these fuses specifically well suited to 48V battery banks, where standard 32V fuses pose a severe risk of sustained arcing during a fault condition. Whether installing a high-capacity inverter charger or building a large-scale lithium battery bank, these fuses deliver dependable safety and performance.
Critical Circuit Protection for 48V Systems
Proper fusing is a mandatory safety requirement for any high-capacity DC system. The Victron 400A ANL fuse is designed to rapidly interrupt fault currents before wiring can overheat or system components sustain damage. Unlike standard automotive fuses that max out at 32V, this robust 80V-rated fuse safely extinguishes arcs in higher voltage applications. This makes it an essential component for modern 48V solar setups and marine power systems. The visible element design allows for quick visual inspection, helping system operators verify the fuse status without requiring a multimeter during troubleshooting.
Key Specifications and Benefits
- High Voltage Tolerance: Rated up to 80V DC, ensuring safe arc suppression in 12V, 24V, and 48V systems.
- Heavy-Duty 400A Rating: Capable of handling substantial continuous currents for large inverters and heavy DC loads.
- Package of Five: Supplied as a convenient five-pack to ensure you have spare fuses on hand for maintenance or multi-circuit installations.
- Visible Element: Allows for immediate visual confirmation of a blown fuse for faster system diagnostics.
- Broad Compatibility: Works seamlessly with Victron single ANL fuse holders and standard aftermarket ANL mounting hardware.
Seamless Component Integration
These 400A ANL fuses are designed to integrate cleanly into your DC distribution setup. They are directly compatible with Victron Energy single ANL fuse holders, ensuring a secure, low-resistance connection that minimises voltage drop across the circuit. For larger installations, these fuses can be implemented alongside Victron modular busbar accessories to efficiently distribute power across multiple heavy loads. Careful selection of fuse sizing and robust holders helps maintain system integrity under continuous heavy current draw.
Ensure your demanding off-grid and marine electrical systems remain protected against critical overcurrent events. Incorporate the Victron 80V 400A ANL Fuse into your DC distribution design for reliable, high-capacity circuit protection.
SPECIFICATIONS
Specifications
| Brand | Victron Energy |
| Part Number | CIP143400020 |
| Fuse Type | ANL |
| Current Rating | 400A |
| Maximum Voltage | 80V DC |
| Package Quantity | 5 Fuses |
| Weight | 0.106 kg |
| SKU: | VIC-CIP143400020 |
| Barcode: | 8719076061786 |
WARRANTY
Victron Energy Limited Warranty Policy
Direct Customers
Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.
End-Users
Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website will provide further guidance on the procedure for end-users to make a claim under this limited warranty.
If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.
Warranty
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.
For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.
During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.
This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
- Reversed battery polarity.
- Inadequate connection.
- Mechanical shock or deformation.
- Contact with liquid or oxidation by condensation.
- Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
- Breakage or damage due to lightning.
- Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
- For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.
This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.
Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.
In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.
If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.
All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.
The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.
Life Support Policy
As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.
Warranty on repairs for products outside their warranty period
The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.
Applicable law
This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.














































