Victron 24V 50A Skylla-TG 24/50 3-phase (1+1) Battery Charger
Victron 24V 50A Skylla-TG 24/50 3-phase (1+1) Battery Charger
50A 3-Phase Input, Dual Outputs, Temperature Compensated

DESCRIPTION
Victron Skylla-TG 24/50: Industrial 3-Phase Battery Charger for Demanding 24V Systems
Precision 3-Phase Charging for Critical 24V Battery Banks
The Victron Skylla-TG 24/50 is a robust, microprocessor-controlled 3-phase battery charger engineered for professional and industrial applications where reliability and precise charge control are paramount. Delivering a full-rated 50 A charge current to your main 24V battery bank, plus a dedicated 4 A output for a starter battery, this unit ensures your entire DC system remains optimally charged. Its 3-phase input (3 x 400 V AC) provides balanced load distribution and higher efficiency, making it ideal for fixed installations in workshops, marine vessels, and off-grid power systems.
Unlike generic chargers, the Skylla-TG employs an advanced IUoUo three-step charge characteristic, rapidly and safely recharging batteries while preventing overcharge. The microprocessor continuously monitors and adjusts the process, significantly extending battery service life, particularly for sealed, maintenance-free batteries where precise voltage control is critical to avoid drying out and premature failure.
Key Features
- 3-Phase Input: 3 x 400 V AC for efficient, balanced power draw and reduced line current per phase
- Dual Isolated Outputs: 50 A main output plus 4 A auxiliary output to maintain starter batteries
- Adaptive IUoUo Charging: Microprocessor-controlled three-step charge profile for faster, safer charging
- Temperature Compensation: Included battery sensor adjusts voltage to prevent overcharge in high temperatures
- Voltage Sense: Compensates for cable losses, ensuring the battery receives the exact charge voltage
- Power Supply Mode: Stabilised output allows use as a DC power supply without batteries connected
- Remote Alarm: Potential-free contacts (NO/NC) for integration with monitoring systems
- Rugged Build: Aluminium enclosure with forced cooling, rated for -40 to +50 °C operation
Engineered for Battery Longevity
Battery health depends on precise charging. The Skylla-TG’s temperature compensation actively reduces charge voltage as ambient or battery temperature rises, a vital feature for sealed AGM or gel batteries that are sensitive to overvoltage. Combined with voltage sensing that eliminates voltage drop errors over long cable runs, your batteries are charged exactly to specification, maximising cycle life and reducing total cost of ownership.
Versatile Power Solution
Beyond battery charging, the Skylla-TG functions as a highly stabilised DC power supply. This dual-purpose capability is invaluable for bench testing, powering DC equipment directly, or acting as a buffer in systems without batteries. The integrated remote alarm with potential-free contacts allows seamless integration into building management or vessel monitoring systems, providing alerts for charger status or fault conditions.
Built for Harsh Environments
Housed in a durable blue aluminium case (RAL 5012) with forced cooling, the Skylla-TG operates reliably in ambient temperatures from -40 to +50 °C and up to 95% non-condensing humidity. Comprehensive protection against output short circuits, reverse polarity, over-temperature, and excessive battery voltage safeguards both the charger and your valuable battery investment. The M8 stud terminals (Approx. 5/16") provide secure, low-resistance connections for heavy-duty cables.
Applications
- Marine and yacht 24V house and starter battery banks
- Industrial off-grid and backup power systems
- Workshop and service centre battery maintenance
- Mobile equipment and heavy vehicle charging
- Telecom and remote monitoring installations
Equip your 24V system with the charging precision and durability it demands. Order the Victron Skylla-TG 24/50 today and ensure your batteries deliver peak performance and extended service life.
SPECIFICATIONS
Specifications
| Input Voltage (V AC) | 3 x 400 V AC |
|---|---|
| Input Voltage Range (V AC) | 320-450 V AC |
| Input Voltage Range (V DC) | N/A |
| Frequency (Hz) | 45-65 Hz |
| Power Factor | 1 |
| Charge Voltage Absorption (V DC) | 28.5 V DC |
| Charge Voltage Float (V DC) | 26.5 V DC |
| Charge Current House Batt. (A) | 50 A |
| Charge Current Starter Batt. (A) | 4 A |
| Charge Characteristic | IUoUo (Three Step) |
| Temperature Sensor | Yes |
| Can Be Used As Power Supply | Yes |
| Remote Alarm | Potential Free Contacts 60 V / 1 A (1x NO and 1x NC) |
| Forced Cooling | Yes |
| Protection | Output Short Circuit; Battery Reverse Polarity Detection; Battery Voltage Too High; Temperature Too High |
| Operating Temp. Range | -40 to +50 °C (-40 - 122 °F) |
| Humidity (Non-Condensing) | Max 95% |
| Material & Colour | Aluminium (Blue RAL 5012) |
| Battery Connection | M8 Studs |
| Protection Category | IP 21 |
| Dimensions H x W x D | 365 x 250 x 257 mm |
| Safety | EN 60335-1, EN 60335-2-29 |
| Emission | EN 55014-1, EN 61000-3-2 |
| Immunity | EN 55014-2, EN 61000-3-3 |
| SKU: | VIC-STG024050300 |
| Barcode: | 8719076026679 |
| Model #: | STG024050300 |
| MPN: | STG024050300 |
WARRANTY
Victron Energy Limited Warranty Policy
Direct Customers
Victron Energy provides the following warranty to any direct customer (OEM, distributor or dealer) in relation to any products that Victron Energy has directly sold to the direct customer. This warranty is not an end-user warranty between Victron Energy and an end-user, and end-users shall not have any rights or remedies under this limited warranty towards Victron Energy directly. The direct customer shall, in turn, ensure that the end-user is provided with a warranty identical to this warranty, subject to applicable local mandatory law.
End-Users
Victron Energy may also provide a warranty directly to end-users, in which case the below warranty conditions equally apply to such warranty. In that case, end-users shall claim their warranty at their place of purchase or through the original direct customer of Victron, which can be found through the support section on Victron’s website https://www.victronenergy.com/support. Hence, the direct customer shall on behalf of Victron Energy deal with any warranty claims made under any warranty that Victron Energy may provide directly to end-users. This support section on Victron’s website https://www.victronenergy.com/support will provide further guidance on the procedure for end-users to make a claim under this limited warranty.
If the end-user is a consumer – a natural person who is acting for purposes which are outside that person's trade, business, craft or profession – the following applies. The rights and remedies granted to the consumer under this limited warranty are without prejudice to the consumer’s statutory rights. Furthermore, the consumer is entitled by law to remedies from the seller free of charge in the event of a lack of conformity of the goods (such as repair, replacement, price reduction or rescission), which remedies are not affected by this limited warranty.
Warranty
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries: 2 years from date of purchase by the original end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries: 3 years from date of purchase by the original end-user, with a maximum of 42 months from the Victron Energy invoice date. In addition to this, proof of correct battery usage is required when making a battery warranty claim.
For a 10% surcharge on the current net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased by Victron’s direct customers, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before the expiration of the original term. Victron may ask proof that the product was still functional at the time of purchase of the extended warranty.
During the warranty period, Victron Energy will, at its discretion, repair, replace or (partly) credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation.
This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
- Reversed battery polarity.
- Inadequate connection.
- Mechanical shock or deformation.
- Contact with liquid or oxidation by condensation.
- Use in an inappropriate environment (dust, corrosive vapour, humidity, high temperature, biological infestation, etc.).
- Breakage or damage due to lightning.
- Connection terminals and screws destroyed or other damages, like overheating, due to insufficient tightening.
- For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone other than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.
This warranty and our warranty obligations thereunder (repair, replacement or credit) are the direct customer’s and, if applicable, the end-user’s sole rights and remedies and our sole obligations with respect to any defective and/or non-conforming product or breach of warranty and is subject to and without prejudice to the limitations of liability in this warranty.
Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be made with the merchant, or if he is either unable or not allowed to provide service, direct contact should be made with Victron Energy through the support section on Victron’s website.
In case Victron Energy replaces a product, it will own the replaced product. Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products.
If Victron Energy repairs or replaces a part of a product, its warranty term is not extended: the warranty will apply for the remaining term of the original warranty term. For example, if Victron Energy replaces a product with a 5-year warranty after 3 years, the warranty of this product will apply for another 2 years, with a minimum of 6 months.
All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages.
The foregoing limited warranty provided by Victron Energy is in lieu of any other warranties, express or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, of any kind whatsoever including, without limitation, warranties of merchantability or fitness for a particular purpose, with respect to any product. The above is without prejudice to the arrangement for consumers detailed above.
Life Support Policy
As a general policy, Victron Energy does not recommend the use of any of its products in life support applications where failure or malfunction of Victron Energy's product can be reasonably expected to cause the failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the liability of Victron Energy is adequately protected under the circumstances.
Warranty on repairs for products outside their warranty period
The warranty period on products that are outside their warranty period and have been repaired by Victron Energy or one of the Victron Energy Repair centres is six (6) months from delivery. The same applies to spare parts and circuit boards that have been supplied or repaired by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions of this warranty is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions of this warranty.
Applicable law
This warranty is exclusively governed by the laws of the Netherlands, to the exclusion of the UN Convention on Contracts for the International Sale of Goods.
Contact details
Victron Energy B.V. | De Paal 35, 1351 JG Almere, The Netherlands | https://www.victronenergy.com/support