How to Read Solar Panel Specifications: Decoding STC, Voc and More

How to Read Solar Panel Specifications: Decoding STC, Voc and More

This guide to solar panel specifications explains the ratings printed on a panel’s label or datasheet: Standard Test Conditions (STC), Normal Operating Cell Temperature (NOCT) and the rated outputs—open-circuit voltage (Voc), short-circuit current (Isc), voltage and current at maximum power (Vmp and Imp) and maximum power (Pmax).

Specification What it means What to check it against
Voc (open-circuit voltage) Voltage with nothing connected; the highest voltage the panel produces The controller’s maximum PV input voltage, after allowing for cold weather
Isc (short-circuit current) Current with the leads shorted together; the highest current at STC The controller’s PV current limit, string fuses and cable size
Vmp (voltage at maximum power) Operating voltage at the panel’s best power point The controller’s operating range; PWM or MPPT choice
Imp (current at maximum power) Operating current at the panel’s best power point Expected charging current from the array
Pmax (maximum power) Rated wattage: Vmp × Imp at STC Array size and the controller’s maximum array wattage

Standard test conditions (STC)

To enable comparisons between different panels, the performance of all panels are specified against a set of conditions used industry-wide called Standard Test Conditions (i.e. cell temperature of 25°C and an irradiance of 1000W/m2 with an air mass 1.5 [AM1.5] spectrum). These conditions are extremely unlikely to occur in real life. 

Normal Operating Cell Temperature (NOCT)

NOCT provides power ratings that are lower but more realistic. So instead of 1000W/m2 it uses 800 W/m2, which is closer to a reasonably sunny day with scattered clouds. It uses an air temperature of 20°C instead of solar-cell temperature, and takes into account a 1m/s breeze cooling the back of a tilted solar panel. This is applicable to a conventional glass and aluminium framed panel mounted on a building or ground array but not a lightweight panel laid horizontally (which will obviously run hotter!)

Newer datasheets often quote NMOT (Nominal Module Operating Temperature) instead of NOCT. It uses the same 800W/m², 20°C air temperature and 1m/s wind, but the panel is measured while delivering power rather than at open circuit, so NMOT and NOCT figures are not directly comparable.

Rated Output Specifications

Open-Circuit Voltage (Voc)

The open circuit voltage is the maximum voltage that the solar panel can produce with no load on it (i.e. measured with a multimeter across the open ends of the wires attached to the panel). If two or more panels are wired in series it will be Voc of panel 1 + Voc of panel 2, etc. The voltage is generally highest mid-morning as the sun rises rapidly and the panel temperature is still quite low. The array’s cold-weather Voc (see Temperature Coefficients below) must be less than the maximum solar voltage permitted by the solar-charge controller. Some controllers shut down if it’s exceeded, while some may continue to operate but the lifespan of the controller could be compromised or it may result in immediate destruction of the device. Allowing 3.5 per cent only covers cells down to about 12–13°C; on colder mornings Voc rises further, so calculate the cold-weather Voc from the panel’s temperature coefficient (see Temperature Coefficients below).

Short-Circuit Current (Isc)

Short-circuit current is the current that flows out of the panel when the positive and negative leads are shorted together. The current can be measured by passing the current through a multimeter configured to measure amps (this does not harm the panel, but care must be taken to avoid arcing). Make sure the meter’s current range is higher than the panel’s Isc—many multimeters are limited to 10A—and see our guide to testing a solar panel’s output with a multimeter. The Isc + 20 per cent is recommended to determine the required current handling capacity of a compatible solar-charge controller. This is the highest current the solar panels will produce under standard test conditions – note that under a clear sky, at midday in summer, and tilting the panel towards the sun you could get significantly more current. 

Voltage at Maximum Power (Vmp)

The voltage at maximum power is the voltage when the power output is the greatest. It is the actual voltage you want to see when it is connected to the MPPT controller under standard test conditions. In practice the actual Vmp will vary during course of a day and with temperature, shading, soiling of the panel surface, etc. You can measure this voltage with a multimeter at the solar input terminals of an MPPT controller during bulk-charge mode.

Current at Maximum Power (Imp)

The Imp is the current (amps) when the power output is the greatest. It is the actual amperage you want to see when it is connected to an MPPT controller under standard test conditions in bulk-charge mode. The actual current varies with sun strength on the panel. Note that the current that a PWM controller will receive is slightly higher than the Imp under standard test conditions.

Maximum Power Point (Pmax)

The Pmax is the sweet spot of the solar panel power output, where the combination of the volts and amps results in the highest wattage (volts x amps = watts).The ‘smarts’ inside an MPPT controller periodically measures the panel voltage under varying loads and then adjusts the solar input circuit to balance the volts and amps and maximise the power output during bulk-charge mode. The wattage that a solar panel is listed as is the Pmax where Pmax = Vmp x Imp at standard test conditions.

Temperature Coefficients

Datasheets also list temperature coefficients, which show how the ratings change as the cell temperature moves away from the 25°C used for STC. Typical crystalline panels have:

  • Pmax: about −0.25 to −0.40% per °C, so output falls as the panel heats up.
  • Voc: about −0.25 to −0.30% per °C, so voltage rises in cold weather.
  • Isc: a small positive value, about +0.05% per °C.

To check a controller’s maximum PV voltage, calculate the cold-weather Voc: Voc × (1 + Voc coefficient × (25 − lowest cell temperature)), using the coefficient as a positive number. For example, two panels with a Voc of 24.1V wired in series give 48.2V at STC. With a Voc coefficient of −0.28% per °C and a cell temperature of 0°C on a cold, clear morning, the array reaches 48.2V × (1 + 0.0028 × 25) ≈ 51.6V. That exceeds a 50V controller limit, even though the old rule of thumb of Voc + 3.5 per cent (49.9V) would not.

Choose the Right Solar Panel for Your Needs

Understanding these technical specifications is essential when selecting the right solar panel for your needs. To ensure you’re choosing a panel that will deliver optimal power in your specific conditions, take the time to consider your expected solar panel output based on your location. We offer a wide range of high-quality solar panels designed to perform well under various conditions. Our team can provide detailed information about each panel's STC, NOCT, and rated output specifications to help you make the most informed decision. Whether you're setting up a caravan, bus, tiny house, boat, superyacht or large off-grid project, our panels are designed to provide reliable, efficient, and sustainable energy. Explore our solar panel range to find the perfect fit for your needs.

Compare Voc, Vmp, Isc and dimensions across panels in our RV & Caravan Solar Panel Comparison Tool, then use our solar charge controller guide and solar panel wiring guide to match the array to a controller.