Wakespeed 2m WS500 CANBus to Victron Crossover Cable
Wakespeed 2m WS500 CANBus to Victron Crossover Cable
2m VE.Can Integration Cable with 120-Ohm Termination Resistor

DESCRIPTION
Optimised Alternator Control and System Integration
Achieve flawless communication between your advanced alternator regulator and your power management network with the Wakespeed 2m WS500 CANBus to Victron Crossover Cable. Designed specifically to bridge the communication gap between Wakespeed and Victron Energy systems, this purpose-built cable ensures your power setup operates safely and efficiently. Standard Ethernet cables do not share the correct pinout for this application, making this specific crossover lead an essential component for any integrated marine or mobile power system.
Seamless VE.Can Network Communication
Integrating a high-output alternator into a modern lithium battery system requires precise data sharing. By connecting your Wakespeed WS500 directly to a Victron GX device, such as the Cerbo GX, this cable allows the regulator to receive real-time data from your battery management system (BMS). This closed-loop communication enables the WS500 to dynamically adjust alternator output based on accurate battery voltage, current, and temperature readings. The result is an optimised charging profile that maximises charging efficiency while protecting expensive battery banks from overcharging or thermal stress.
Colour-Coded for Error-Free Installation
Setting up complex CAN networks can be challenging, but this crossover cable simplifies the process with clear, colour-coded RJ45 connectors. The black connector is pinned specifically for the WS500 alternator regulator, while the blue connector matches the pinout required for Victron VE.Can ports and compatible third-party systems. This visual guide reduces the risk of incorrect connections, saving valuable installation time and preventing potential communication faults.
Robust Build for Marine and Mobile Environments
Vibration, moisture, and movement are constant factors in boats, caravans, and off-grid vehicles. To combat these harsh conditions, the crossover cable features protective rubber boots over both RJ45 terminations, providing crucial strain relief and protecting the delicate pins from dust and physical damage. The two-metre cable length offers generous reach, allowing for flexible mounting options between your alternator regulator and your central communication hub without creating excess cable clutter.
Essential Network Termination Included
A stable CAN bus network requires proper termination at both ends of the communication line to prevent signal reflection and data packet loss. To ensure your network functions flawlessly out of the box, this package includes a dedicated RJ45 connector featuring a built-in 120-ohm CAN bus termination resistor. This terminator is designed to plug directly into the open CAN port on the Wakespeed WS500, completing the network loop and ensuring robust, interference-free data transmission.
Key Features
- Purpose-Built Pinout: Specifically wired to connect Wakespeed regulators to Victron VE.Can networks.
- Generous Length: Two-metre cable suits typical marine, RV, and off-grid installation layouts.
- Colour-Coded Connectors: Black RJ45 for the WS500 and Blue RJ45 for Victron systems ensure correct orientation.
- Protective Boots: Individual rubber boots protect terminations from damage and provide strain relief.
- Included Terminator: Comes complete with a 120-ohm RJ45 termination resistor for the WS500 network port.
Upgrade Your Power System Communication
Ensure your high-output alternator and power management network are working in perfect harmony. Add the Wakespeed to Victron crossover cable to your setup today to enable intelligent, data-driven battery charging for your mobile or marine application.
SKU: WS-WS500-WS-VE-2M
SPECIFICATIONS
| SKU: | WS-WS500-WS-VE-2M |
WARRANTY
WAKESPEED WARRANTY
Wakespeed® warrants the original purchaser the product is free from any defects in material or workmanship for a period of two years from the original date of purchase. If any such defect is discovered within the warranty period, Wakespeed will repair or replace the product free of charge, subject to verification of the defect or malfunction upon delivery or shipping prepaid to Wakespeed.
Defects or physical damage resulting from abuse, neglect, accident, improper repair, alteration, modification, or unreasonable use of the products are not covered under warranty. Returned products showing evidence of tampering and/or unapproved access to internal components will not be supported under warranty. Wakespeed cannot warranty Broken cases, parts damaged by fire, water, freezing, collision, theft, explosion, rust, corrosion, damaged cables or wiring harnesses, or items damaged in shipment in route to Wakespeed Warranty Services for repair. Wakespeed assumes no responsibility for consequential damage or loss or expense arising from these products or any labor required for service or repair.
Wakespeed will not repair or be held responsible for any product sent without proper identification and return address or Return Authorization number clearly marked on the package. You must include proof of date and place of purchase (photocopy of purchase invoice) or we cannot be responsible for repairs or replacement. In order to expedite warranty claims, Wakespeed requires that a Return Authorization is completed prior to returning a defective product for repair.
If factory service is required, contact Wakespeed Support at 775-221-8898 or email support@wakespeed.com, Monday through Friday, 8:30 AM to 4:30 PM, (PST). Repair or replacement of the defective part or product is to be supplied free of charge upon delivery of the defective product to Wakespeed Warranty Service. Customer is responsible for all return transportation charges and any air, international or rush delivery expense.
FCC COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.














































