Solar Power Estimate Calculator | SPEC

Live solar load builder

Average Daily System Balance | 2 Days Battery Autonomy

Darwin - Winter
Loads150 AhDaily use
Solar charge173 AhInto battery
PV array524 WAt STC
Battery333 AhTotal bank

Kitchen

80.63 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
32
48
0
0.63
0

Electronics

35.3 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
12.5
2
0.5
0.3
20
0

Pumps

1.67 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
1.67
0

Entertainment

4.16 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
3.83
0.33
0
0

Medical

21 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
21
0

Lighting

6.67 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
6.67

Ventilation

1 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
1

240V via inverter

0 Ah/day
UseApplianceWatts (average)AmpsHoursRunAh/day
0