{"product_id":"victron-energy-meter-et340-3-phase-max-65a-phase","title":"Victron Energy Meter ET340 - 3 phase - max 65A\/phase","description":"\u003ch2 class=\"sectionedit2\" id=\"introduction_and_usage\" style=\"box-sizing: border-box; padding: 0px; line-height: 1; clear: left; font-size: 2rem; margin: 3rem 0px 1.5rem; color: rgb(39, 38, 34); font-family: MuseoSans-700, sans-serif;\"\u003e1. Introduction and usage\u003c\/h2\u003e  \u003cdiv class=\"level2\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(39, 38, 34); font-family: MuseoSans-300, sans-serif; font-size: 15.872px;\"\u003e \u003cp style=\"box-sizing: border-box; margin: 0.5rem 0px 0px; padding: 0px;\"\u003eThis document is the manual for the 3 phase max 65A per phase Energy Meter.\u003c\/p\u003e  \u003cp style=\"box-sizing: border-box; margin: 1.5rem 0px 0px; padding: 0px;\"\u003eThe Energy Meter can be used to:\u003c\/p\u003e  \u003col style=\"box-sizing: border-box; margin: 1rem 0px 0px; padding-right: 0px; padding-left: 1.5em; list-style-position: outside; list-style-image: initial;\"\u003e \t\u003cli class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \t\u003cdiv class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003eGrid meter, and used as control input for an ESS System (1).\u003c\/div\u003e \t\u003c\/li\u003e \t\u003cli class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \t\u003cdiv class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003eMeasure the output of a PV Inverter\u003c\/div\u003e \t\u003c\/li\u003e \t\u003cli class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \t\u003cdiv class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003eMeasure the output of a AC Genset\u003c\/div\u003e \t\u003c\/li\u003e \u003c\/ol\u003e  \u003cp style=\"box-sizing: border-box; margin: 1.5rem 0px 0px; padding: 0px;\"\u003eThe meter is connected to the Color Control GX. There are two options in its wiring:\u003c\/p\u003e  \u003cp class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003e \u003c\/p\u003e  \u003col style=\"box-sizing: border-box; margin: 1rem 0px 0px; padding-right: 0px; padding-left: 1.5em; list-style-position: outside; list-style-image: initial;\"\u003e \t\u003cli class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \t\u003cdiv class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003eDirect connection, either using the RS485 to USB interface with 1.8m cable length, or the 5.0m cable.\u003c\/div\u003e \t\u003c\/li\u003e \t\u003cli class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \t\u003cdiv class=\"li\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(51, 51, 51);\"\u003eWireless connection via Zigbee\u003c\/div\u003e \t\u003c\/li\u003e \u003c\/ol\u003e  \u003cdiv class=\"level4\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(39, 38, 34); font-family: MuseoSans-300, sans-serif; font-size: 15.872px;\"\u003e \u003cp style=\"box-sizing: border-box; margin: 1.5rem 0px 0px; padding: 0px;\"\u003eWhen used to measure a PV Inverter, terminals 1, 2 and 3 should face the PV inverter to ensure correct direction of current and power.\u003c\/p\u003e \u003c\/div\u003e  \u003ch4 id=\"single_phase_dual_function_diagram\" style=\"box-sizing: border-box; padding: 0px; line-height: 1; clear: left; font-size: 1.5rem; margin: 3rem 0px 0px; color: rgb(39, 38, 34); font-family: MuseoSans-700, sans-serif;\"\u003eSingle phase dual function diagram:\u003c\/h4\u003e  \u003cdiv class=\"level4\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(39, 38, 34); font-family: MuseoSans-300, sans-serif; font-size: 15.872px;\"\u003e \u003cp style=\"box-sizing: border-box; margin: 0.5rem 0px 0px; padding: 0px;\"\u003eIn this diagram, a single meter is used to both measure the grid and a single phase PV Inverter\u003c\/p\u003e \u003c\/div\u003e  \u003cp class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \u003c\/p\u003e  \u003cp class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \u003c\/p\u003e  \u003cp class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e\u003cspan style=\"color: rgb(39, 38, 34); font-family: MuseoSans-300, sans-serif; font-size: 15.872px;\"\u003eOn the CCGX go to the grid meter in the Wired AC sensor settings. Make sure 'Phase type' is set to 'Single phase' and 'PV inverter on phase 2' is enabled.\u003c\/span\u003e\u003c\/p\u003e  \u003cp class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \u003c\/p\u003e  \u003cp class=\"level1\" style=\"box-sizing: border-box; padding: 0px; margin: 0px 0px 0px 1.5em; color: rgb(102, 102, 102);\"\u003e \u003c\/p\u003e  \u003ch3 class=\"sectionedit7\" id=\"option_bwired_connection_to_ccgx\" style=\"box-sizing: border-box; padding: 0px; line-height: 1; clear: left; font-size: 1.8rem; margin: 3rem 0px 1.5rem; color: rgb(39, 38, 34); font-family: MuseoSans-700, sans-serif;\"\u003eWired connection to CCGX\u003c\/h3\u003e  \u003cdiv class=\"level3\" style=\"box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(39, 38, 34); font-family: MuseoSans-300, sans-serif; font-size: 15.872px;\"\u003e \u003cp style=\"box-sizing: border-box; margin: 0.5rem 0px 0px; padding: 0px;\"\u003eConnect the Energy Meter to the CCGX using the USB to RS485 cable. The RS485 to USB interface cable between the CCGX and the Energy Meter can be extended up to 100 meters; make sure that the extensions of the Data+ (orange) and Data- (yellow) wires form a twisted pair.\u003c\/p\u003e  \u003cdiv class=\"table sectionedit8\" style=\"box-sizing: border-box; margin: 0px 0px 1.4em; padding: 0px; overflow-x: visible;\"\u003e \u003ctable class=\"inline\" style=\"box-sizing: border-box; margin: 1rem 0px 0px; padding: 0px; border-collapse: collapse; empty-cells: show; border-spacing: 0px; border: 1px solid rgb(204, 204, 204); min-width: 50%;\"\u003e \t\u003cthead style=\"box-sizing: border-box;\"\u003e \t\t\u003ctr class=\"row0\" style=\"box-sizing: border-box;\"\u003e \t\t\t\u003cth class=\"col0\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); background-color: rgb(238, 238, 238); text-align: left;\"\u003eRS485 Converter\u003c\/th\u003e \t\t\t\u003cth class=\"col1\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); background-color: rgb(238, 238, 238); text-align: left;\"\u003eEnergy meter\u003c\/th\u003e \t\t\u003c\/tr\u003e \t\u003c\/thead\u003e \t\u003ctbody style=\"box-sizing: border-box;\"\u003e \t\t\u003ctr class=\"row1\" style=\"box-sizing: border-box;\"\u003e \t\t\t\u003ctd class=\"col0 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eYellow (Data-)\u003c\/td\u003e \t\t\t\u003ctd class=\"col1 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eTerminal 9\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"row2\" style=\"box-sizing: border-box;\"\u003e \t\t\t\u003ctd class=\"col0 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eOrange (Data+)\u003c\/td\u003e \t\t\t\u003ctd class=\"col1 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eTerminal 8\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"row3\" style=\"box-sizing: border-box;\"\u003e \t\t\t\u003ctd class=\"col0 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eBlack (GND)\u003c\/td\u003e \t\t\t\u003ctd class=\"col1 leftalign\" style=\"box-sizing: border-box; padding: 0.3em 0.5em; margin: 0px; vertical-align: top; border: 1px solid rgb(204, 204, 204); white-space: nowrap;\"\u003eTerminal 10\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e  \u003cp style=\"box-sizing: border-box; margin: 1.5rem 0px 0px; padding: 0px;\"\u003eThe red, green and brown wire coming out of the USB to RS485 cable are not used.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e ","brand":"Victron","offers":[{"title":"Default Title","offer_id":42037219360829,"sku":"VIC-REL300300000","price":206.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/3918\/3933\/files\/victron-et340-3-phase-energy-meter-vic-rel300300000.png?v=1770174505","url":"https:\/\/www.solar4rvs.com.au\/products\/victron-energy-meter-et340-3-phase-max-65a-phase","provider":"Solar 4 RVs","version":"1.0","type":"link"}